Application Scope - Technical characteristics
Compressed gas balance and gas consumption measurement
Gas leakage/leakage rate detection
Measurement of portable compressed gas at the front end of a single unit/shop
Flow measurement of processing gases such as nitrogen, carbon dioxide, oxygen, argon, nitrous oxide, etc
Flow measurement of nitrogen generators
High measurement accuracy due to fixed measurement (inlet and outlet parts), also in the low measurement range (is the ideal choice for measuring leakage degree)
Heat measurement principle, no additional pressure and temperature measurement, no mechanical moving parts
Flowmeters follow a calorimetric principle: sensors heated in the process are cooled by the gas flowing through them. The cooling rate depends on the flow rate of the gas, so the cooling rate depends on the flow rate to get the measurement index. Therefore, no additional pressure and temperature compensation is required.
Given its compact design, the device can monitor all compressed air systems from compressors to small pneumatic tools (1/4 to 2 "). Specially designed for compressed gas and nitrogen. Other gases such as nitrogen, carbon dioxide, argon, nitrous oxide and other models can be separately inquired.
Installation is simple and fast. The special advantage lies in the mobility of the measuring equipment. The measuring equipment can be removed quickly for calibration or cleaning without the need to move the entire measuring site.